Sensata Technologies : Control Products
Brazil/Brasil   Simplified Chinese   Traditional Chinese   Europe   Japan
Search Sensata:
The World Depends on Sensors and Controls
*
Products
 
 
Commercial Breakers:
    Circuit Breaker
2–40 Amp
C Series
    Circuit Breaker
12.5–60 Amp
7851, 7854
    Circuit Breakers
35–150 Amp
F Series
    Circuit Breakers
35–150 Amp
6766–19
    Circuit Breaker
35–150 Amp
S Serie
s
    Circuit Breaker
 
Precision Breakers:
    Circuit Breaker
2–35 Amp
PS series
    Circuit Breaker
2–40 Amp
Small Frame P
    Circuit Breakers
    Circuit Breaker
35–150 Amp
Large Frame P
Support
 
 
 
 
 
 
 
 
 
Contacts
 
 
See Also
 
 
 


Site Updated 3 Dec. 2008
* * * Sensata > Products > Controls > Circuit Breakers > Thermal >

Klixon® S Series: SDLA, SDLM, and SLA
35 to 150 Amp, Commercial, Ignition Protected Thermal Breakers


Ignition protected

Using a bimetal, snap acting disc as the sensing and actuating element, the Klixon® SDLA and SDLM series thermal circuit breakers provide trouble–free over current protection for harsh environments.

Available in the three configurations:
SLA: Open construction, automatic reset
SDLA: Sealed construction, automatic reset
SDLM: Sealed construction, manual reset


Applications

Main harness, accessory and equipment protection for heavy trucks, busses, construction equipment, off–road vehicles, and RV’s
Battery protection in electric vehicles
Circuit protection of truck lift–gates
Over–current protection in battery chargers


General Envelope Dimensions
Nominal dimensions provided for reference only.

Views of 6790 circuit breaker

* * *
Klixon
Thermal Circuit Breakers

Request pricing for this item. We offer a broad array of custom solutions. Click here!

Contact a product specialist.

Request more info

Have a question? Email Klixon now. Click here.



Trip Curve
Approximate Time — Current Characteristics at 77°F (25°C)


Trip Curve Diagram


Derating Curve
Approximate Effect of Ambient Temperature on Ultimate Trip


Diagram: Approximate effect of ambient temperature on ultimate trip
Performance characteristics are based on room temperature (77°F). Consult derating curve at left for ambient temperatures significantly higher or lower than standard room temperature.

Example: At 77°F the device is calibrated to hold at 100% of rated current (1) and trip at 135% of rated current (2). At 140°F, the same device will hold at approximately 78% of rated current (3), and trip at approximately 115% of rated current (4).
The World Depends on Sensors and Controls